feat(isn): VLAN-4 routed sub-interface + addr on spine ISN ospfIf; ISN-CSW LLDP neighbor (v0.19.0)
Real ACI multi-site spines carry the OSPF address toward the ISN on a
routed sub-interface, not the bare port: ospfIf id/dn are now
eth1/{49+si}.4 with addr=172.16.{site}.{si+1}/24 (same /24 as the
existing .254 peer); ospfAdjEp nests under the sub-if. Each spine ISN
uplink physical port also gets an ISN-CSW lldpAdjEp/cdpAdjEp
(sysName ISN-CSW{site}, portIdV Ethernet1/{si+1}, model N9K-C9364C,
locally-administered 02:1B:0D MAC hashed from site.id). Single-site
fabrics build none of this. Closes the autoACI Fabric (physical) gap
where spine uplink rows showed blank Local IP / Neighbor Port.
908 tests green.
This commit is contained in:
+2
-1
@@ -299,7 +299,7 @@ PR-19: the ISN/IPN spine uplink `l1PhysIf.mtu` is now `isn.mtu`-driven (default
|
||||
`cdpAdjEp`(dn,sysName,mgmtIp,devId,portId,platId,ver,cap) ·
|
||||
`lldpInst`🆕(dn,adminSt,name,holdTime,initDelayTime,txFreq,ctrl,optTlvSel) · `lldpIf`🆕(dn has `if-[eth{s}/{p}]`,id,adminRxSt,adminTxSt,operRxSt,operTxSt,mac,portDesc,portVlan,sysDesc,wiring) ·
|
||||
`cdpInst`🆕(dn,adminSt,name,holdIntvl,txFreq,ver,ctrl) · `cdpIf`🆕(dn has `if-[eth{s}/{p}]`,id,adminSt,operSt) ·
|
||||
`isisAdjEp`(dn,operSt,sysId,lastTrans,numAdjTrans) · `isisDom` · `ospfAdjEp`(dn,operSt,id,peerIp/addr,nbrId,area) · `ospfIf`✅(name,area,state,helloIntvl,deadIntvl) · `arpAdjEp`✅(ip,mac,ifId,physIfId,operSt).
|
||||
`isisAdjEp`(dn,operSt,sysId,lastTrans,numAdjTrans) · `isisDom` · `ospfAdjEp`(dn,operSt,id,peerIp/addr,nbrId,area) · `ospfIf`✅(name,area,state,helloIntvl,deadIntvl,addr) · `arpAdjEp`✅(ip,mac,ifId,physIfId,operSt).
|
||||
LLDP/CDP fidelity (v0.12.0): `lldpAdjEp`/`cdpAdjEp` are now enriched with real-APIC-shaped fields
|
||||
(`portIdV`/`portId` carry the NEIGHBOR's own port; `chassisIdV` is a deterministic per-node MAC,
|
||||
see `build/neighbors.py:node_mac`; `sysDesc`/`platId`/`ver` describe the neighbor's model+version, or
|
||||
@@ -312,6 +312,7 @@ target-subtree-class=lldpAdjEp`) returned `totalCount=0` because the root DN had
|
||||
`--json` for machine-readable output).
|
||||
PR-19: `ospfIf.area`/`ospfAdjEp.area` are now `isn.ospf_area`-driven (default `"0.0.0.0"`) instead of a hardcoded literal.
|
||||
PR-20: `ospfIf.helloIntvl`/`deadIntvl` are new, driven by `isn.ospf_hello`/`isn.ospf_dead` (defaults 10/40, real ACI defaults) — previously not carried on this MO at all.
|
||||
PR-22: the ISN-facing `ospfIf`/`ospfAdjEp` on each multi-site spine now sit on a routed VLAN-4 sub-interface (`id`/dn `eth1/{49+si}.4`, was the bare physical port `eth1/{49+si}`) and `ospfIf` gained an `addr` attribute (`172.16.{site.id}.{si+1}/24`) — matching real ACI multi-site spines, which carry the ISN OSPF address on a sub-if rather than the physical port. The underlying physical port's `l1PhysIf`/`ethpmPhysIf` (interfaces.py) are unchanged. Each spine's ISN uplink physical port also gained a simulated `lldpAdjEp`/`cdpAdjEp` (`sysName=ISN-CSW{site.id}`, `portIdV=Ethernet1/{si+1}`, model `N9K-C9364C`) via `build/fabric.py`, the third `add_adjacency` call site — see docs/DESIGN.md's "PR-22" section.
|
||||
|
||||
**Overlay/BGP:** `bgpInst`(dn,asn) · `bgpPeer`(dn,asn,addr,type,peerRole) ·
|
||||
`bgpPeerEntry`(dn,addr,operSt∈{established,...},rtrId,lastFlapTs,connEst,connDrop,type) ·
|
||||
|
||||
+44
-1
@@ -81,7 +81,7 @@ Each sub-builder is `build(topo, site, store)` and only ADDS MOs. `orchestrator.
|
||||
Sub-builders (one concern each, <~200 lines):
|
||||
- `fabric.py` — fabricNode (roles/ids/model/serial/version from YAML), topSystem, fabricHealthTotal, vpcDom/vpcIf (border-leaf pair), infraWiNode.
|
||||
- `cabling.py` — fabricLink (with `/lnk-…/` DN), lldpAdjEp + cdpAdjEp derived STRICTLY from the cabling graph, isisAdjEp.
|
||||
- `underlay.py` — bgpInst (local ASN), ospfAdjEp/**ospfIf**✅ (spine↔leaf), IS-IS dom.
|
||||
- `underlay.py` — bgpInst (local ASN), ospfAdjEp/**ospfIf**✅ (spine↔ISN, on the routed VLAN-4 sub-if `eth1/{49+si}.4` with `addr` — PR-22; multi-site only), IS-IS dom.
|
||||
- `overlay.py` — intra-site BGP-EVPN (spines as RR, leaves as clients): bgpPeer/bgpPeerEntry(established)/bgpPeerAfEntry;
|
||||
**ISN**: on each spine's `sys/bgp/inst`, add inter-site bgpPeer with peer addr /32 + remote (other-site) ASN.
|
||||
- `endpoints.py` — fvCEp/fvIp distributed across leaves+EPGs (encap/fabricPathDn consistent), epmMacEp/epmIpEp, fvIfConn.
|
||||
@@ -827,3 +827,46 @@ regression gate this project's acceptance bar calls for (autoACI sandbox e2e, ac
|
||||
that gate exists to catch (a hardcoded node-count assertion inside autoACI itself, if one exists, would
|
||||
only surface there). The main thread's independent re-run of the real Ansible/aci-py/autoACI chains on
|
||||
ACI hardware is the authoritative backward-compat gate for this PR.
|
||||
|
||||
## PR-22 — ISN OSPF routed sub-interface + ISN CSW LLDP neighbor
|
||||
|
||||
**Design intent:** autoACI's Topology "Fabric (physical)" view derives per-spine ISN uplink rows from
|
||||
`ospfIf` (port + local IP), `ospfAdjEp` (remote IP), and `lldpAdjEp` (CSW-side port). Pre-PR-22, the sim
|
||||
modeled the ISN-facing `ospfIf` as a **plain interface** (`eth1/{49+si}`) with **no address**, and there
|
||||
was no LLDP neighbor on that port at all — so the demo UI showed `Port=eth1/49`, `Local IP=-`,
|
||||
`Neighbor Port=-`. Real ACI multi-site spines instead use a **routed sub-interface** (VLAN-4 encap, e.g.
|
||||
`eth1/49.4`) that carries the OSPF address, while the ISN switch advertises LLDP on the underlying
|
||||
physical port. This PR makes the sim match that reality.
|
||||
|
||||
### `build/underlay.py` — `ospfIf` becomes a VLAN-4 routed sub-interface
|
||||
|
||||
`ospfIf.id`/dn now read `eth1/{49+si}.4` (was `eth1/{49+si}`), and the MO gained a new `addr` attribute:
|
||||
`172.16.{site.id}.{si+1}/24` — the same `/24` as the existing OSPF peer `172.16.{site.id}.254`, so the
|
||||
adjacency stays subnet-consistent. `area`/`helloIntvl`/`deadIntvl`/`operSt` are unchanged. `ospfAdjEp`'s
|
||||
dn moves under the new sub-if segment (`if-[eth1/{49+si}.4]` instead of `if-[eth1/{49+si}]`); its
|
||||
`peerIp`/`nbrId`/`operSt`/`area` attrs are unchanged. The underlying physical port
|
||||
(`l1PhysIf`/`ethpmPhysIf`, built by `build/interfaces.py`) is **untouched** — only the OSPF logical
|
||||
interface becomes a sub-interface; LLDP/physical port state stays on the plain port, matching real
|
||||
hardware (a routed sub-if never carries its own LLDP/physical-layer identity). Consumers resolve the
|
||||
underlying port via `ifId.split('.')[0]` — the same fallback autoACI's topology code uses.
|
||||
|
||||
### `build/fabric.py` — ISN CSW LLDP/CDP neighbor
|
||||
|
||||
Each spine's ISN uplink **physical** port (`eth1/{49+si}`) now gets a simulated LLDP/CDP neighbor via the
|
||||
shared `add_adjacency()` helper (`build/neighbors.py`) — the third of that module's three call sites,
|
||||
placed directly after the existing APIC↔leaf adjacency loop in `fabric.py`'s `build()`. Fields:
|
||||
`sysName=ISN-CSW{site.id}`, `portIdV=Ethernet1/{si+1}` (the CSW's own port numbering), `mgmtIp=
|
||||
172.16.{site.id}.254` (the same IP the OSPF adjacency already peers with), `model=N9K-C9364C`,
|
||||
`version=n9000-10.2(5)`. The neighbor's chassis MAC uses a deliberately different OUI-shaped prefix
|
||||
(`02:1B:0D:...`, locally-administered per the 802 "locally administered" bit) than `node_mac()`'s
|
||||
`00:1B:0D:...` used for real fabric/controller nodes, keyed by `site.id` (one ISN CSW device per site,
|
||||
not per spine) — this guarantees no collision with any real node's chassis MAC regardless of ID overlap.
|
||||
|
||||
Gate: both changes are multi-site only (`len(topo.sites) > 1`, the same condition `underlay.py`'s
|
||||
ISN OSPF block already used) — a single-site fabric builds no `ospfDom`/`ospfIf`/`ospfAdjEp` and no
|
||||
`lldpAdjEp` named `ISN-CSW*`, unchanged from pre-PR-22 behavior.
|
||||
|
||||
New/updated tests: `tests/test_pr19_tier2.py` (`TestIsnOspfSubInterfaceAndLldp` — sub-if id/addr shape,
|
||||
`ospfAdjEp` nesting, `lldpAdjEp` fields, single-site negative case);
|
||||
`tests/test_pr3b_batch1.py`/`tests/test_pr5_topology_consistency.py` (`ospfIf`/`ospfAdjEp` port-resolution
|
||||
assertions updated to strip the `.4` suffix before matching against `l1PhysIf`).
|
||||
|
||||